Audi 80/90/Coupe

Since 1986-1991 of release

Repair and car operation



Audi 80/90/Coupe
+ 1.2. Car identification
- 2. Engines, carburettors
   2.1.2. Removal and engine installation (5-cylinder models)
   2.1.3. Dismantling and assemblage of engines
   2.1.4. A head of the block of cylinders, the mechanism timing
   + 2.2. An engine electric equipment
   - 2.3. Carburettors
      - 2.3.1.2. Check and carburettor adjustment
         2.3.1.3. Check of turns of idling
         2.3.1.4. Check and adjustment of maintenance CO
         2.3.1.5. Fast check of functioning of the carburettor
         2.3.1.6. Check of a probe of Ljambda
         2.3.1.7. Check of the gauge of temperature of a cooling liquid
         2.3.1.8. Check of an air diaphragm
         2.3.1.9. Check of a potentiometer of a throttle
         2.3.1.10. Carburettor preset values 2EE
      + 2.3.2. Carburettors Keihin
3. Greasing system
+ 4. Cooling system
+ 5. Fuel system
+ 6. An exhaust system
+ 7. Ignition system
+ 8. Transmission
+ 9. Suspension brackets, wheels
+ 10. Brake system
+ 11. A steering
+ 12. A body, salon
+ 13. A central air
+ 14. An electric equipment


32ad0625

2.3.1.7. Check of the gauge of temperature of a cooling liquid
THE GENERAL DATA

The temperature gauge informs the management equipment on engine temperature. Depending on this temperature the diaphragm regulator establishes its position. In case of damage of the gauge of temperature there can be difficulties at engine start at low temperature as the diaphragm will not be completely closed.

PERFORMANCE ORDER
1) remove a plug from the gauge of temperature and measure its resistance. At temperature +20 ° With it should equal 2000–3000 Ohm
2) connect a plug to the temperature gauge, start the engine and warm up it to normal working temperature
3) muffle the engine, repeat measurement of resistance which at temperature +90 ° With should equal 200–300 Ohm

Changes of resistance depending on temperature are presented on the schedule.

Resistance of the gauge
It is in details possible to make check of the gauge of temperature, placing it in a vessel with water and gradually warming up it. At the moment of heating of water to the corresponding temperature, measure resistance of the gauge.

In case of difference in the measured sizes, it is necessary to replace the temperature gauge.